Sidebar
LD MULTICHANNEL control instruments are a series of multiple reading digital systems that meet a wide range of applications.
EMEC - Digital Controller - LDPHCLH PPM Controller, Multi Function Control
LD MULTICHANNEL
CONTROL INSTRUMENT
LD MULTICHANNEL control instruments are a series of multiple reading digital systems that meet a wide range of applications.
They are multiple digital measuring systems for complete control of water treatment and chemicals dosage, ensuring, depending on model, the control on acid (pH) and on a second parameter (by customer request different parameters combination can be set).
LD MULTICHANNEL instruments have: easy control by encoder wheel, flow control, local & remote control, ERMES web communication, permanent data storage with system log, PT100 temperature probe, stand-by input, alarms, programmable delay at dosing start-up (up to 60 minutes), priority dosage, probe readout menu and check-up, multiple probe readings can be viewed, working modes (on/off, impulsive proportional, proportional PWM and fixed PWM), automatic or manual dosing activity, chlorine/bromine selection with ECL6 (LDPHCL), flocculant output 230 VAC (LDPHCL and LDPHRH) and mA output (optional).
MEASUREMENT PARAMETERS
- pH
- ORP
- Chlorine
- Chlorine Dioxide
- Hydrogen Peroxyde
- Ozone
WORKING MODE
- PID
CONFIGURATION
BASIC
- RS485 output for connection to pc or instruments
ETHERNET
- RS485 output to link other EMEC instruments or a PC
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
2G - 3G
- RS485 output to link other EMEC instruments or a PC
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
- Alarm messages via SMS
FEATURES
- 2 PROGRAMMABLE CHANNELS
- REMOTE CONTROL ETHERNET or 2G/3G option configurations are remotely manageable through portal: www.ermes-server. com.
- SOFTWARE Instrument software in English language. French and german available upon request
- CUSTOMIZATIONS Instruments are customizable with client logo on frontal panel
- PERMANENT DATA STORAGE (WITHOUT BATTERY) with system log on display
- DISPLAY Multiple probe readings
- Alarms and connection status can be viewed on display
- Stand-by input
- FLOW CONTROL
- DELAYED START-UP Programmable delay at dosing start-up (up to 60 minutes)
- PROBE DIAGNOSTICS Probe diagnostics menu
- mA OUTPUT (option)
- ALARM RELAIS Alarm output 230 VAC.
- AUTOMATIC OR MANUAL DOSING ACTIVITY
- PH PRIORITY DOSAGE
- ALARMS Alarms: damaged probes - max dosage - threshold - 2 levels - flow
Additional Information
Owners Manual
Data Sheet
Please call for questions or technical assistance! 714-564-9100